Cleveland Cascades supplied two new Resitain valves to be retro-fit to the two existing potash loading chutes located in Port Moody, Vancouver, Canada.
A Cleveland Cascades Engineer supported with the installation and commissioning of the New Resitain Valves in Early March 2020.
The Resitain valve is fitted on the base of the carrier and is designed to close the exit of the Cascade Chute when the loading operation has been completed.
A motor driven actuator operates two ‘trap doors’. The doors hang vertical when the valve is open and swing together and seal the exit when closed.
A set of pre-adjusted limits are fitted and tested by Cleveland Cascades during the assembly of the Units and then commissioned on site. These limits will be set at the fully open and fully closed positions.
An image of the Resitain valve installed can be seen above. This was mimicked for both chutes.